UL 1672

UL 1672​

Application

Internal wiring of electrical, electronic and medical equipment.


Product Description

Standard UL, CUL

Conductor Solid , Strand and OS-1 either tinned or bare copper

Rating UL 1617 105° C 600V

       UL 1618 80° C 300V

       UL 1672 105° C 300V

Flammability UL VW-1, CUL FT1

Insulation Heat resistant PVC which is RoHS Complied wire.

Usage Uniform thickness of wire to ensure easy stripping and cutting

            Resistant to acids, oils, alkalines, moisyure and fungus

Download

UL Style

CUL Type

Conductor

Insulation

Thickness

Jacket

Thickness

Overall

Diameter

Approx

Standard Put-Up

Conductor

Resistance at 20 °C

(AWG)

(No./mm)

(mm)

(mm)

(mm)

(ft/coil)

(M/coil)

(ohm/km)

UL 1617

AWM I / II A

(Stranded)

25

7/0.160

0.76

0.25

2.60

2000

610

150.00

24

11/0.160

2.70

2000

610

94.20

22

17/0.160

2.90

2000

610

59.40

20

21/0.180

0.40

3.40

2000

610

36.70

18

34/0.180

3.60

2000

610

23.20

16

26/0.253

3.90

2000

610

14.60

14

41/0.253

4.30

2000

610

8.96

12

65/0.253

4.80

2000

610

5.64

10

105/0.253

5.80

2000

610

3.54

UL 1618

AWM I A

(Stranded)

26

7/0.160

0.38

0.40

2.10

2000

610

150.00

24

11/0.160

2.30

2000

610

94.20

22

17/0.160

2.40

2000

610

59.40

20

21/0.180

2.60

2000

610

36.70

18

34/0.180

2.90

2000

610

23.20

16

26/0.253

3.20

2000

610

14.60

14

41/0.253

3.50

2000

610

8.96

12

65/0.253

4.00

2000

610

5.64

10

105/0.253

5.10

2000

610

3.54

UL 1672

AWM I / II A

24

11/0.160

0.38

0.40

2.30

2000

610

94.20

22

17/0.160

2.40

2000

610

59.40

20

21/0.180

2.60

2000

610

36.70

18

24/0.180

2.90

2000

610

23.20